  • Six Current Methods for Monitoring The Effectiveness of Sterilization⑤

    2024-09-23

    PCD test (★★★★★) A PCD test is used to test the sterilization effectiveness of Class A cavity loads. It is an upgrade of the chemical indicator and BD tests, and is the most difficult sterilization effect test to pass. It consists of a 1.5-meter-long tube with a 1.5mm internal diameter, closed at on Read More
  • Six Current Methods for Monitoring The Effectiveness of Sterilization④

    2024-09-19

    BD test (★★★☆☆) The BD test is the short name for the Bowie-Dick Test, which is used to evaluate the cold air discharge and saturated steam penetration of sterilizers. The BD test should not be performed in a "cold chamber" state when the device is first started each day, as it does not reflect norm Read More
  • Six Current Methods for Monitoring The Effectiveness of Sterilization③

    2024-09-16

    Biological test (★★★☆☆) Biological tests are used as a specific biological indicator, and usually consist of a carrier containing bacterial spores with specific resistance to sterilization conditions, placed in the most difficult location in the sterilizer. After the sterilization process, these bio Read More
  • Six Current Methods for Monitoring The Effectiveness of Sterilization②

    2024-09-12

    Chemical indicator test (★★☆☆☆) The chemical indicator test is a simple and rapid method used to monitor whether the sterilization process has met predetermined conditions. Chemical indicators are often composed of special chemicals that change color under specific sterilization conditions, such as Read More
  • Six Current Methods for Monitoring The Effectiveness of Sterilization①

    2024-09-09

    Air leakage test (★★★★☆) The air leakage test is an important check for detecting any air leakage in the sterilizer. By regularly performing this test, seal issues can be identified and repaired in a timely manner, ensuring the effectiveness of the sterilization procedure. Sterilizers typically com Read More
  • How does the YESON Fast-Drying sterilizer ensure good sterilization?

    2024-09-02

    Every time the YESON Fast-Drying sterilizer is vacuumized, it is pumped to at least -82Kpa; an alarm will sound if it is not pumped. Even in continuous high-intensity operation, the vacuum degree can still reach below -82Kpa, which ensures the sterilization effectiveness. The YESON Fast-Drying ster Read More
  • Total 11 pages  Go to Page
  • Go
we are the manufacturer of the chain of sterilization products incl autoclave,ultrasonic cleaner,handpiece lubricator,and pouch sealer in China.

QUICK LINKS

PRODUCTS

CONTACT US

  +86-574-87006889
  enquiry@yeson-medicine.com
  No. 1 huanzhen Dadao, Hengjie, Haishu 315181 Ningbo,China
© 2022 NINGBO HAISHU YESON MEDICAL DEVICE CO., LTD . All rights reserved. Privacy Policy  Sitemap  Supported by leadong.com